Clean and blow out
all debris from under the machine base.
Be sure that all
vent holes are open and free of debris.
When the base is
clean, wet the area under the base with a hose so the grout will flow.
Mix the grout to a
pourable consistency.
With a 1"
pencil vibrator, pour the grout through the center hole in the
machine. Vibrate and add grout until the grout is coming out through
all vent holes.
Allow the grout to
cure for three days before operating the machine.
Non-shrink grout
must be used. Type V-1 Unisorb or equivalent (Unisorb Installation
Technologies - Jackson, Michigan).
Once grouting has
begun, it must be completed in one pour to prevent a cold joint.